The Precepten range of conventional control panels is
a powerful yet user-friendly series of control panels. They are
designed and manufactured to a high standard and is approved by
the Loss Prevention Certification Board (LPCB) to EN54-2 and EN54-4
and also tested and approved to Singapore Standard CP10:2005. The
Precepten range has earned a reputation over many years
for quality and reliability and is recognised as market leader in
many countries around the world. This latest generation takes advantage
of the very latest technological advancements both in terms of design
and manufacturing techniques to meet the exacting requirements of
the latest European standards.
From 2 to 32 zones (up to 32 detectors
per zone) • EN54-2 approval by LPCB • Comprehensive end-user facilities
(access level 2) • Designed & built using the latest technology
for optimum performance and consistently high quality • Extensive
configurable facilities for the engineer via DIL switches • 4 alarm
circuits as standard (4 zone panel and above) • Up to 5 fully-functional
repeaters - 2-wire RS485 • Range of EN54 compliant power supply
modules, designed to meet the specific load requirements of each
size panel • Zonal one-man test feature and sounder one-man test
facility • Short Circuit to fire setting for use with older type
detectors • Panel inputs for class change, evacuate, silence alarms,
system reset • 3 open collector outputs for evacuate, buzzer active,
disablement active • Auxiliary supply output - monitored fuse •
Panel expansions boards for open collector, relay and alarm outputs
• Optional timer clock/counter module Assessed to ISO 9001: 2000
Certificate • Surface or semi-flush mounting as standard • Ample
termination space • Robust fire resistant red steel enclosure •
Log book and manual supplied • Complies with EMC and LVD directives
>>>
back to products menu
The CB200 conventional panel may be supplied in 1, 2, 4 or 8 zone
formats. It complies with the requirements of EN54 Part 2. All zones
and alarm circuits are monitored for open and short circuit fault
conditions with detector removal facility also provided as standard.
The cabinet will house 2 x 12V 2.1AH S.L.A. batteries
wired in series, which will sustain an 8 zone panel for up to 24
hours. All panels have a zone 1 non-latch facility to enable panel
interlinking without Ïlock-upÓ occurring. The class change input
enables the alarm circuits to operate without panel indication or
panel latching.
The cabinet back-box houses only the transformer,
thus providing a virtually empty enclosure for first fix installation.
A steel gland plate, removable plastic grommets and ample space
are designed to assist with cable termination. A slide-in insert
is included for clear zone identification. The surface-mount electronics
motherboard is fitted and terminated after first fix installa-tion.
Finally a terminal cover completes the panel installation.
The 4 & 8 zone panels will accommodate up to 3 repeater panels,
which are connected by a shielded 2- core data cable where the repeater
panels are powered locally, or an additional 2-core may be run from
the panel for power (Max. 1 repeater may be powered from the panel).
Built-in detector removal indication facility •
From 1 to 8 zones • 4 Alarm circuits on 4-8 zone panels • Conforms
to the requirements of EN54-2 • User-friendly access code • One-man
test facility • Non-latching zone feature • Class change input •
Earth fault monitoring • Fully-functional repeater available (4
& 8 zone panels only) • Removable cable-entry grommets • User-friendly
controls • Surface or semi-flush mounting as standard • Ample termination
space • Flame-resistant polycarbonate enclosure • Log book and manual
supplied • Complies with EMC and LVD directives
>>>
back to products menu
The Armstrong 6024ARM alarm bell is an easy to install, maintenance
free signaling device designed to cater for the needs of Fire Detection
System with Central Control Equipment. This low current, high performance
bell, services the needs of most adverse condition providing fewer
working parts, easy installation, high level sound output. Providing
a clear warning to personnel during emergency. The 6024ARM alarm
bell is designed to EN-54 with built in varistor to meet the EMC
requirement.
>>>
back to products menu
Continuing our policy of bringing our customers the ultimate effectiveness
in fire detection that current technology allows, Series 65 has
been developed from the highly successful Series 60 range of conventional
detectors.
Series 65 incorporates well-proven sensing technologies,
together with advances in materials and electronics technology,
including an IC based on that used in XP95 analogue addressable
detectors.
Having a wide operating voltage of 9-33V, the Series
65 detectors can be integrated into security systems, when used
with a relay base.
The Series 65 wide voltage range consists of ionisation,
integrating ionisation and optical smoke detectors, 4 grades of
heat detector and a range of bases. The detectors are identical
in appearance to Series 60.
wide operating voltage • advanced electronic technology
• flashing LED option • magnetic test switch option • can be used
on security systems • proven detection performance • designed to
meet approvals worldwide
>>>
back to products menu
The Armstrong 3020ARM Call Point are designed to offered uncompromising
quality and realiability regardless of configurations in the aspect
of installation efficiency, flexibility and full compliance with
the latest BS 5839: PT2 and EN54: PT 11. To facilitate the compatibility
to majority of central control equipment manufactured in the world.
A variety of monitoring resistors value are available by request
to make Armstrong Call Point easily adopted to most fire alarm system
world wide. The Call Point are constructed from fire retardants
ABS engineering plastic thus withstand high impact strength and
high resistance to heat.
Designed to meet BS 5839: PT2 and EN54: PT 11.
Each contact provided double terminal for independent input and
output connections especially for looping to ensures perfect continuity.
Variety of colours available. Special tool operating test facility.
Simple but secure and comply with health and safety requirement.
Protective film on glass thus protecting the operator from glass
fragments.
>>>
back to products menu |