Listings by Brand

Listings by Category

Armstrong Precepten Control Panels

General Introduction
The Precepten range of conventional control panels is a powerful yet user-friendly series of control panels. They are designed and manufactured to a high standard and is approved by the Loss Prevention Certification Board (LPCB) to EN54-2 and EN54-4 and also tested and approved to Singapore Standard CP10:2005. The Precepten range has earned a reputation over many years for quality and reliability and is recognised as market leader in many countries around the world. This latest generation takes advantage of the very latest technological advancements both in terms of design and manufacturing techniques to meet the exacting requirements of the latest European standards.

From 2 to 32 zones (up to 32 detectors per zone) • EN54-2 approval by LPCB • Comprehensive end-user facilities (access level 2) • Designed & built using the latest technology for optimum performance and consistently high quality • Extensive configurable facilities for the engineer via DIL switches • 4 alarm circuits as standard (4 zone panel and above) • Up to 5 fully-functional repeaters - 2-wire RS485 • Range of EN54 compliant power supply modules, designed to meet the specific load requirements of each size panel • Zonal one-man test feature and sounder one-man test facility • Short Circuit to fire setting for use with older type detectors • Panel inputs for class change, evacuate, silence alarms, system reset • 3 open collector outputs for evacuate, buzzer active, disablement active • Auxiliary supply output - monitored fuse • Panel expansions boards for open collector, relay and alarm outputs • Optional timer clock/counter module Assessed to ISO 9001: 2000 Certificate • Surface or semi-flush mounting as standard • Ample termination space • Robust fire resistant red steel enclosure • Log book and manual supplied • Complies with EMC and LVD directives

 

Armstrong CB200 Conventional Panel

General Introduction
The CB200 conventional panel may be supplied in 1, 2, 4 or 8 zone formats. It complies with the requirements of EN54 Part 2. All zones and alarm circuits are monitored for open and short circuit fault conditions with detector removal facility also provided as standard.

The cabinet will house 2 x 12V 2.1AH S.L.A. batteries wired in series, which will sustain an 8 zone panel for up to 24 hours. All panels have a zone 1 non-latch facility to enable panel interlinking without Ïlock-upÓ occurring. The class change input enables the alarm circuits to operate without panel indication or panel latching.

The cabinet back-box houses only the transformer, thus providing a virtually empty enclosure for first fix installation. A steel gland plate, removable plastic grommets and ample space are designed to assist with cable termination. A slide-in insert is included for clear zone identification. The surface-mount electronics motherboard is fitted and terminated after first fix installa-tion.

Finally a terminal cover completes the panel installation. The 4 & 8 zone panels will accommodate up to 3 repeater panels, which are connected by a shielded 2- core data cable where the repeater panels are powered locally, or an additional 2-core may be run from the panel for power (Max. 1 repeater may be powered from the panel).

Built-in detector removal indication facility • From 1 to 8 zones • 4 Alarm circuits on 4-8 zone panels • Conforms to the requirements of EN54-2 • User-friendly access code • One-man test facility • Non-latching zone feature • Class change input • Earth fault monitoring • Fully-functional repeater available (4 & 8 zone panels only) • Removable cable-entry grommets • User-friendly controls • Surface or semi-flush mounting as standard • Ample termination space • Flame-resistant polycarbonate enclosure • Log book and manual supplied • Complies with EMC and LVD directives

 

Control Equipment Precept Panel (Conventional & Marine)

General Introduction

  • Membrane facia with tactile switches
  • LPCB approved to BS 5839 part 4
  • From 2 to 32 zones
  • A one-man test facility
  • User-friendly controls
  • Easily removable chassis
  • Removable cable - entry grommets
  • Zonal and relay outputs
  • Non-latching zonal feature
  • Selectable pulsed/continuous sounder outputs
  • A wider range of available accessories
  • Complies with EMC and LVD Directives

 

Control Equipment Discovery Panel (Addressable)

General Introduction

  • From 1-4 loops
  • LPCB approval to EN54 parts 2 and 4
  • Full Apollo XP95 and Discovery compatibility
  • Automatic recognition of Apollo or CEL outstations
  • Extensive mode change options by day/night and special group allocation
  • Windows-based, full upload/download PC software package 500mA output per loop with highly stable voltage platform, even under mains-failed conditions
  • Installer-configurable access codes
  • Fully networkable with graphics package, network repeaters and other CEL analogue addressable control panels
  • Powerful processing and extensive panel & loop I/O capability
  • User friendly controls and a clear, unambiguous screen
  • Membrane facia with tactile switches
  • Complies with EMC & LVD Directives

 

Control Equipment Nexus Panel (Addressable)

General Introduction

  • Aesthetic design
  • From 1 to 8 loops (Apollo XP95 protocol)
  • A clear, backlit display with zonal indication option
  • User-friendly controls
  • Membrane facia with tactile switches
  • Powerful processing ability
  • Windows-based software download package
  • Alarm sensitivity & delay adjustments
  • Messages edited by PC or keyboard
  • Fully networkable with graphics package, konex network repeaters and other nexus panels
  • Designed to meet BS 5839 part 4
  • Complies with EMC and LVD Directives

 

Control Equipment Voyager Panel (Addressable)

General Introduction

  • From 1-2 loops
  • Compliant with EN54 parts 2 and 4, BS EN 60950 and BS EN 50130 part 4
  • Full Apollo XP95 and Discovery compatibility
  • Automatic recognition of Apollo or CEL outstations
  • Extensive mode change options by day/night and special group allocation
  • Windows-based, full upload/download PC software package
  • 500mA output per loop with highly stable voltage platform, even under mains-failed conditions
  • Fully networkable with other voyager and discovery panels, graphics package and integra network repeaters
  • Powerful processing and extensive panel and loop I/O capability
  • User friendly controls and a clear, unambiguous screen
  • Membrane facia with tactile switches
  • Complies with EMC and LVD Directives

 

Eltek Delta Net and Delta Compact

General Introduction
A Delta Net network is Eltek's solution to decentralised networked fire alarm installations, and uses Delta OP panels as user interface - for alarm indication and system operation - and the required number of Delta DA modules. The Delta DA module can drive two analogue detector loops, each with up to 126 addressable loop components - detectors, manual call points, sounders, emergency lighting luminaries, etc.

The communication solutions allow practically unlimited connections of Delta OP and Delta Repeater, peripherals such as Delta FireWin PCbased operation, printers and interface with other monitoring systems. You establish a network over a wide-spread area using fibre optic connections between the network parts.

In centralised solutions, the Delta Technology is concentrated in the Delta Compact fire alarm panel, which contains one Delta OP panel, one Delta DA module, power supply and battery backup. Also, a mimic panel or diagram can be built in its front. The built in Delta DA module can drive two analogue detector loops for connection of up to 126 addressable loop components per loop.

The Delta Compact can be expanded with several analogue detector loops by connecting external Delta DA modules and additional battery backup. The Delta Compact fire alarm panel can also be networked as a module in an existing Delta Net installation.

 

Eltek Delta Op Operating Panel

General Introduction
Delta Op is a new and elegant operating panel developed for both centralised and decentralised operation of Eltek's fire alarm systems.

Delta Op enables you to hide cabinets with DA modules, batteries, terminals, etc. in technical rooms. The whole fire alarm system can be operated from the attractive Delta Op panel.

Delta Op is a micro processor-based operating panel designed for connection to the Delta Op and ANX95 families of fire alarm systems.

The Delta Op panel is the interface between you and the system and represents the vital nerve centre of the fire alarm system.

All system activity - fire, pre-alarms, faults, the exact location of the alarm, etc. - is presented via the graphic display and LEDs. The operator communicates with the system with the aid of function keys and the numeric keypad.

Key Features

  • Small, elegant and cost effective main control panel with functional design
  • Cutting-edge technology
  • ANX95 compatible
  • Compliance with European Standard EN 54 Part 2
  • Discovery Detector Range Support
  • Reliable and flexible control and monitoring system
  • Centralised fire alarm system Configuration
  • Direct network connection for maximum flexibility
  • Delta Logic+, expanded Fireguard Logic signal processing facility

 

Eltek Fireguard ANX95 Analogue Addressable

General Introduction
A cost-effective analogue addressable fire alarm system suitable for a whole range of building applications.

The ANX95 is a flexible microprocessor-controlled fire alarm panel from Eltek Fire & Safety, offering ease of system design with completely programmable zones and alarm outputs.

All system activity - fire, fault conditions, the precise alarm location, etc. - is annunciated via an alphanumeric display and LED's.

The operator communicates with the system using function keys and the numeric keypad.

Approvals
The ANX95 panel has been subjected to extended noise immunity testing to conform to the VDE0871, Class B. The panel is also approved to the Norwegian FG-specifications and to major industrial and marine standards, and withstands difficult environmental conditions.

Fire Detection & Alarm System Key Features

  • Small, elegant and cost-effective panel
  • High noise immunity
  • Modular system design
  • Cutting-edge micro-processor technology
  • RS232 computer interface
  • Networking facility
  • Built-in battery backup
  • CE marked
  • Wide range of approvals
  • User-friendly menu driven operation